The CX-CL1550 is a Call station designed for the CX-1000 series IP communication system. 
By connecting this station to a network (LAN or WAN), hands-free voice conversations can be made using this station or other intercom stations. It is also possible to receive broadcasts made by other CX stations, audio interfaces, and amplifier units. Power can be supplied from a PoE-compatible switching hub (in this case, an optional AC adapter is not required). The CX-CL 1550 supports the SIP protocol, which allows conversations with general-purpose SIP phones via the System manager.

Power Source PoE (IEEE802.3af compliant) or 12 V DC (use of the optional AC adapter)
Current Consumption PoE: 140 mA, 12 V DC (AC adaptor): 390 mA
Power Consumption 5.5 W
Speech Method Hands-free: Full-duplex (echo canceler + voice switch)
Frequency Response Conversation/Broadcast: 300 Hz - 7 kHz
Hands-free Speaker: Dynamic type speaker, maximum output 2.0 W
Microphone: Omni-directional digital MEMS microphone x 2
External Speaker Maximum output 2.0 W, 8 0, push-in terminal (2 pins)
Signal Processing Input channel: Gain, EQ x 2, Comp, AGC, noise canceler, echo canceler, voice switch, microphone array, speech enhancement
Output channel: Gain, EQ x 7, ANC
Network Network I /F: 100Base-TX
Network protocol: TCP/IP, UDP, ARP, ICMP, HTTP, RTP, RTSP, IGMP, NTP, SIP, FTP, RSTP Audio packet transmission method: Unicast, Multicast
Number of broadcasting destinations: Unicast (max. 16), Multicast (max. 2999) Connector: RJ45 connector x 2 (LAN A ( PoE compatible), LAN B ( PoE incompatible)) Network cable: UTP (Cats or greater)
Audio Transmission Sampling frequency: 16 kHz, 8 kHz (controllable on the software)
Audio codec: PCM, G. 722, G. 711 µ-Law/A-Law
Quantization bit depth: 16-bit
Voice packet loss recovery: Silence insertion
Operation Direct key x 1
Indicators LED indicators: RUN (green) x 1, STATUS (yellow, red, green) x 1, Calling indicator (yellow) x 1, Conversation indicator (green) X 1, Unlock indicator (green) x 1
Control Input 4 channels, no-voltage make contact input, open voltage: 12 V DC, short-circuit current: 5 mA or less, push-in terminal (5 pins)
Control Output 1 channel, relay contact output, withstand voltage: 30 V DC, maximum control current: 1 A, push-in terminal (2 pins)
4 channels, open collector output, maximum contact capacity: 30 V DC/100 mA, push-in terminal (5 pins)
Installation Method Flush-mounting or wall-mounting
Impact Resistance  IKO8
Dust/Water Protection IP65 (Note that front cover edges must be sealed at installation.)
Operating Temperature -40 ° c to +60° c
Operating Humidity 90 %RH (no condensation)
Finish Case: Die-cast aluminum, silver, mat finish, paint Panel: PC resin
Dimensions 115 (W) x 162 (H) x 72.2 (D) mm
Weight 750g
Accessory Waterproof washer ·-4, Tamper-proof screw ·-4
Option AC adapter: AD-1210P, AD-121 SP
Compatible Box For flush mount: 3-gang electrical box or Back Box YC-150 (option)
For wall mount: Wall-mount Box YS-13A (option)

Note: An AC adapter, when used as power source, cannot be put in the YS-13A, YC-150, or a 3-gang electrical box together with the CX-CL 1550 because such boxes do not have enough room to accommodate both.